Features and Benefits
-
Configuration is
exceptionally easy
-
Slave mode supports 16
TCP masters and up to 62
serial slaves at the
same time
-
Master mode supports 32
TCP slaves at the same
time
-
Emergency request
tunnels ensure QoS
control
-
Serial redirector
function provided
-
Embedded Modbus protocol
analyzer
-
Redundant dual DC power
inputs
-
Built-in Ethernet
cascading for easy
wiring
Overview
The MB3170 and MB3270 are
advanced Modbus gateways
that provide maximum
flexibility for integrating
industrial Modbus networks
of all types and sizes. They
are designed to integrate
Modbus TCP, ASCII, and RTU
devices in almost any master
and slave combination,
including serial master to
serial slave, or
simultaneous serial and
Ethernet masters. A special
priority control feature
allows urgent commands to
obtain immediate response.
All models are ruggedly
constructed, are DIN-rail
mountable, and offer
built-in optical isolation
for serial signals as an
option.
Integration of TCP masters
without alteration to Modbus
RTU/ASCII network or
software
The MB3270 can integrate
Modbus TCP with Modbus
RTU/ASCII,without modifying
the existing Modbus
RTU/ASCII architecture or
software. With the serial
redirector function, a
serial master can maintain
direct access to serial
slave devices through a
specially mapped serial
port. This allows the serial
and TCP masters to access
serial slaves
simultaneously.
Cascading Ethernet ports for
easy wiring
Advanced models of the
MGate™ MB3000 series have
two Ethernet ports to make
network wiring easier. Dual
Ethernet ports allow users
to string multiple Modbus
gateways together using
standard RJ45 Ethernet
cables, eliminating the need
for a separate Ethernet
switch.
Redundant power inputs
Advanced models of the
MB3000 series have dual
power inputs for greater
reliability. The power
inputs allow simultaneous
connections to two live DC
power sources, so that
continuous operation is
provided even if one power
source fails. The higher
level of reliability makes
these advanced Modbus
gateways ideal for demanding
industrial applications.
Warning by relay output
A relay output is
provided for the Ethernet
link and power input status.
The relay output gives
maintenance engineers an
additional tool for
troubleshooting and
maintenance.
Priority control for urgent
commands (patent pending)
As Modbus networks
increase in size and
complexity, the lag time
between commands and
responses becomes a major
concern. Advanced models of
the MB3000 series provide a
priority control function
for urgent commands,
allowing users to force
certain commands to get an
immediate response.
Depending on your system’s
requirements, different
methods are available to
define which commands
receive priority. |
|
|
• LAN Interface |
|
Number of Ports |
2 |
|
Speed |
10/100 Mbps, Auto
MDI/MDIX |
|
Connectors for
External Antenna |
8-pin RJ45 |
|
Magnetic
Isolation Protection |
1.5 KV built-in |
|
• Serial Interface |
|
Serial Standards |
RS-232/422/485,
software selectable |
|
Number of Ports |
MGate MB3170/3170I:
1
MGate MB3270/3270I:
2 |
|
Connectors |
MB3170/3170I: DB9
male for RS-232,
Terminal block for
RS-422/485
MB3270/3270I: DB9
male x 2 |
|
RS-485 Data
Direction Control |
ADDC® (automatic
data direction
control) |
|
ESD Protection |
ESD Protection: 15
KV for all signals |
|
• Serial
Communication
Parameters: |
|
Baudrate |
50 bps to 921.6 Kbps |
|
Data Bits |
7, 8 |
|
Stop Bits |
1, 2 |
|
Parity |
None, Even, Odd,
Space, Mark |
|
Flow Control |
RTS/CTS, XON/XOFF |
|
• Serial Signals |
|
RS-232 |
TxD, RxD, RTS, CTS,
DTR, DSR, DCD, GND |
|
RS-422 |
Tx+, Tx-, Rx+, Rx-,
GND |
|
RS-485-4w |
Tx+, Tx-, Rx+, Rx-,
GND |
|
RS-485-2w |
Data+, Data-, GND |
|
• Environmental
Limits: |
|
Operating
Temperature |
Standard Models: 0
to 55°C (32 to
131°F)
Wide Temp. Models:
-40 to 75°C (-40 to
167°F) |
|
Storage
Temperature |
-20 to 85°C (-4 to
185°F) |
|
Operating
Humidity |
5 to 95% RH |
|
• Power
Requirements: |
|
Input Voltage |
12 to 48 VDC |
|
Power Connector |
Terminal block |
|
• Regulatory
Approvals |
|
Safety |
UL (UL60950-1), TÜV
(EN60950-1) |
|
EMC |
CE (EN55022 Class A
and EN55024), FCC
Part 15 Subpart B
Class A |
|
Hazardous
Location |
UL/cUL Class 1
Division 2 Groups A,
B, C, D; ATEX Class
1 Zone 2 |
|
Shock |
IEC60068-2-27 |
|
Freefall |
IEC60068-2-23 |
|
Vibration |
IEC60068-2-6 |
|
EN61000-4-2 (ESD) |
Level 3 |
|
EN61000-4-3 (RS) |
Level 3 |
|
EN61000-4-4 (EFT) |
Level 4 |
|
EN61000-4-5
(Surge) |
Level 3 |
|
EN61000-4-6 (CS) |
Level 3 |
|
EN61000-4-8 |
Passed |
|
EN61000-4-11 |
Passed |
|
EN61000-4-12 |
Passed |
|
Marine |
DNV |
|
|
|